最新的USGBC LEED AP Operations + Maintenance - LEED-AP-O-M免費考試真題

A commercial building owner is considering a long-term approach to reduce carbon emissions from a property constructed in the 1970s. The building has outdated HVAC systems, inadequate insulation, and relies on natural gas for heating. The owner is looking to develop a Strategic Decarbonization Plan (SDP) that aligns with major equipment replacement schedules and financial planning.
Which of the following actions should the building owner take first to develop a SDP to reduce the building ' s carbon emissions?

正確答案: C
說明:(僅 Fast2test 成員可見)
Which of the following certification standards should a cleaning and degreasing product comply with to be recognized under the Green Cleaning policy for an industrial and institutional floor care product?

正確答案: A
說明:(僅 Fast2test 成員可見)
Which of the following procedures is included in a facility maintenance audit to assess stewardship performance?

正確答案: B
說明:(僅 Fast2test 成員可見)
Which of the following subsystems requires permanent water metering to meet the Water Efficiency (WE) credit category, WEc2: Advanced Water Metering in a LEED project?

正確答案: C
說明:(僅 Fast2test 成員可見)
A key objective of conducting a human impact assessment during the operational phase of a building project is to

正確答案: A
說明:(僅 Fast2test 成員可見)
Which of the following is a requirement for a building to comply with EAp2: Energy Monitoring and Reporting?

正確答案: A
說明:(僅 Fast2test 成員可見)
A commercial office building is located in an area prone to both flooding and extreme heat events. The facility manager is tasked with developing a comprehensive emergency response plan as part of the requirements to achieve IPc1: Operational Planning for Resilience.
Which of the following actions should the facility manager prioritize when developing the emergency response plan to comply with the credit?

正確答案: B
說明:(僅 Fast2test 成員可見)
Which of the following parking spaces is typically exempt from unbundling when managing sustainable transportation infrastructure and policy?

正確答案: B
說明:(僅 Fast2test 成員可見)
Which of the following is required to report fuel data for a project site where propane is delivered but no installed meters are present, as outlined in the EAp2: Energy Monitoring and Reporting?

正確答案: B
說明:(僅 Fast2test 成員可見)
A 1,500 ft2 (139 m2) mobile home is built in the downtown area of a major city. 90% of the project ' s gross floor will be completed by the time of occupancy. LEED certification is being sought. Which rating system would be the most appropriate one to use?

正確答案: D
說明:(僅 Fast2test 成員可見)

聯系我們

如果您有任何問題,請留下您的電子郵件地址,我們將在12小時內回复電子郵件給您。

我們的工作時間:( GMT 0:00-15:00 )
週一至週六

技術支持: 立即聯繫 

English 日本語 Deutsch 한국어