最新的Juniper Security Support, Professional (JNCSP-SEC) - JN0-696免費考試真題

-- Exhibit -

-- Exhibit -
Click the Exhibit button.
There is an existing chassis cluster connected to the corporate network 192.168.1.0/24. You are asked to connect another department to this VLAN. To achieve this, you add a new chassis cluster to the network. After connecting to the network, the cluster experiences traffic problems. You have verified that the addresses and VLAN IDs are configured correctly.
Referring to the exhibit, which configuration would resolve this problem?

正確答案: A
-- Exhibit --
user@host> show log ibgp-trace
...
Jun 12 10:21:08 10:21:08.367627:CID-0:RT:192.168.2.1/49170->192.168.1.1/179;6> matched
filter ibgp-traffic:
Jun 12 10:21:08 10:21:08.367747:CID-0:RT:packet [64] ipid = 11792, @423f741c
Jun 12 10:21:08 10:21:08.367747:CID-0:RT:---- flow_process_pkt: (thd 2): flow_ctxt type 15,
common flag 0x0, mbuf 0x423f7200, rtbl_idx = 0
Jun 12 10:21:08 10:21:08.367747:CID-0:RT: flow process pak fast ifl 71 in_ifp ge-0/0/3.0
Jun 12 10:21:08 10:21:08.367747:CID-0:RT: ge-0/0/3.0:192.168.2.1/49170->192.168.1.1/179,
tcp, flag 2 syn
Jun 12 10:21:08 10:21:08.367747:CID-0:RT: find flow: table 0x4f161150, hash 15898(0xffff), sa 192.168.2.1, da 192.168.1.1, sp 49170, dp 179, proto 6, tok 7 Jun 12 10:21:08 10:21:08.367747:CID-0:RT: no session found, start first path. in_tunnel - 0,
from_cp_flag - 0 Jun 12 10:21:08 10:21:08.367747:CID-0:RT: flow_first_create_session Jun 12 10:21:08 10:21:08.367747:CID-0:RT:Doing DESTINATION addr route-lookup
Jun 12 10:21:08 10:21:08.367747:CID-0:RT: routed (x_dst_ip 192.168.1.1) from trust (ge-0/0/3.0 in 0) to lo0.0, Next-hop: 92.168.1.1 Jun 12 10:21:08 10:21:08.367747:CID-0:RT:flow_first_policy_search: policy search from zone
trust-> zone loopback-zone (0x0,0xc01200b3,0xb3)
Jun 12 10:21:08 10:21:08.367747:CID-0:RT: policy has timeout 900
Jun 12 10:21:08 10:21:08.367747:CID-0:RT: app 0, timeout 1800s, curr ageout 20s
Jun 12 10:21:08 10:21:08.367747:CID-0:RT: permitted by policy allow-bgp(8)
Jun 12 10:21:08 10:21:08.368250:CID-0:RT: flow_first_install_session======> 0x5394a110
Jun 12 10:21:08 10:21:08.368250:CID-0:RT:flow_first_service_lookup(): natp(0x5394a110):
app_id, 0(0).
Jun 12 10:21:08 10:21:08.368250:CID-0:RT: service lookup identified service 0.
Jun 12 10:21:08 10:21:08.368250:CID-0:RT: flow_first_final_check: in 0/3.0>, out
Jun 12 10:21:08 10:21:08.368250:CID-0:RT: existing vector list 2-49c75930.
Jun 12 10:21:08 10:21:08.368250:CID-0:RT: Session (id:137) created for first pak 2
Jun 12 10:21:08 10:21:08.368250:CID-0:RT: post addr xlation: 192.168.2.1->192.168.1.1.
Jun 12 10:21:08 10:21:08.368250:CID-0:RT:check self-traffic on lo0.0, in_tunnel 0x0
Jun 12 10:21:08 10:21:08.368250:CID-0:RT:retcode: 0xa01
Jun 12 10:21:08 10:21:08.368250:CID-0:RT:pak_for_self : proto 6, dst port 179, action 0x0
Jun 12 10:21:08 10:21:08.368250:CID-0:RT: flow_first_create_session
Jun 12 10:21:08 10:21:08.368250:CID-0:RT: flow_first_in_dst_nat: in , out A> dst_adr
192.168.1.1, sp 49170, dp 179
Jun 12 10:21:08 10:21:08.368752:CID-0:RT: chose interface lo0.0 as incoming nat if.
Jun 12 10:21:08 10:21:08.368752:CID-0:RT: packet droppeD. for self but not interested
Jun 12 10:21:08 10:21:08.368752:CID-0:RT: packet dropped, packet droppeD. for self but not
interested.
Jun 12 10:21:08 10:21:08.368752:CID-0:RT: flow find session returns error.
Jun 12 10:21:08 10:21:08.368752:CID-0:RT: ----- flow_process_pkt rc 0x7 (fp rc -1)
-- Exhibit --
Click the Exhibit button.
You are asked to troubleshoot a new IBGP peering problem on your SRX Series device. The IBGP peering is not establishing.
Referring to the outputs in the exhibit, what is causing the problem?

正確答案: B
You recently configured the antivirus feature profile on your Junos device. The security policy is sending traffic for antivirus scanning. However, the traffic is being blocked and you repeatedly receive the system log message that the scan engine is not ready. You must not allow the traffic to be dropped when the scan engine is not ready.
Which action will resolve this problem?

正確答案: C
-- Exhibit --
{primary:node0}
user@host> show configuration chassis | display inheritance
cluster {
redundancy-group 1 {
node 0 priority 200;
node 1 priority 100;
interface-monitor {
ge-0/0/12 weight 255;
ge-5/0/12 weight 255;
}
}
}
-- Exhibit --
Click the Exhibit button.
A customer reports that their SRX failover is not working as expected. They expected node1 to become the primary node for the control plane when interface ge-0/0/12 failed. However, when ge0/0/12 failed, node0 remained the primary node. They send you the output shown in the exhibit.
What is causing this problem?

正確答案: B

聯系我們

如果您有任何問題,請留下您的電子郵件地址,我們將在12小時內回复電子郵件給您。

我們的工作時間:( GMT 0:00-15:00 )
週一至週六

技術支持: 立即聯繫 

English 日本語 Deutsch 한국어