最新的Huawei HCIP-Transmission V2.5 - H31-341_V2.5-ENU免費考試真題
The decrease of optical power when light passes through a passive optical component is called the____.
(Enter only letters.)
(Enter only letters.)
正確答案:
insertion loss
Explanation:
Insertion loss refers to the decrease of optical power that occurs when light passes through a passive optical component such as connectors, splitters, filters, or splices. This loss results from absorption, scattering, or imperfect coupling within the component. In optical transmission systems, insertion loss is a critical parameter affecting link budget and overall signal quality. HCIP-Transmission materials stress managing insertion loss to ensure sufficient power reaches the receiver and to maintain the integrity of transmitted signals over long distances. Proper component selection and maintenance help minimize insertion loss in WDM systems.
Explanation:
Insertion loss refers to the decrease of optical power that occurs when light passes through a passive optical component such as connectors, splitters, filters, or splices. This loss results from absorption, scattering, or imperfect coupling within the component. In optical transmission systems, insertion loss is a critical parameter affecting link budget and overall signal quality. HCIP-Transmission materials stress managing insertion loss to ensure sufficient power reaches the receiver and to maintain the integrity of transmitted signals over long distances. Proper component selection and maintenance help minimize insertion loss in WDM systems.
If the mask of an IP subnet is 27 bits, how many hosts does the subnet have?
正確答案: B
說明:(僅 Fast2test 成員可見)
Optical layer overhead alarm detection is implemented through optical layer overhead OOS. The R_LOS and MUT_LOS alarms are optical layer alarms and therefore are reported based on OOS detection.
正確答案: A
說明:(僅 Fast2test 成員可見)
In a scenario where non-convergence OTU boards process standard SDH signals, both site A and site B are WDM sites, and the R_LOS alarm is detected on the client side of the OTU board at site A. After an alarm is processed on the WDM side of the OTU board, the REM_5F alarm is reported on the client side of the downstream site B. Then, site B transmits the signals to its downstream client device and reports the R^LOS alarm to the client device.
正確答案: B
說明:(僅 Fast2test 成員可見)
Signal flow analysis is used to check the service flow of a faulty WDM system node by node to locate the fault.
正確答案: B
說明:(僅 Fast2test 成員可見)
OOS overheads are optical-layer overheads. Which of the following statements about OOS overheads is false?
正確答案: C
說明:(僅 Fast2test 成員可見)
Which of the following fiber types complies with the description that the dispersion at 1310 nm is 0 and the typical dispersion coefficient around 1550 nm is 17 ps/nm.km?
正確答案: A
說明:(僅 Fast2test 成員可見)